Metadata-Version: 2.4
Name: di2008-python
Version: 1.4.0
Summary: Python Interface for the DATAQ DI-2008 DAQ
Author-email: Clark Hensley <ch3136@msstate.edu>
Maintainer-email: Clark Hensley <ch3136@msstate.edu>
License: MIT License
        
        Copyright (c) 2018 dataq-instruments
        
        Permission is hereby granted, free of charge, to any person obtaining a copy
        of this software and associated documentation files (the "Software"), to deal
        in the Software without restriction, including without limitation the rights
        to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
        copies of the Software, and to permit persons to whom the Software is
        furnished to do so, subject to the following conditions:
        
        The above copyright notice and this permission notice shall be included in all
        copies or substantial portions of the Software.
        
        THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
        IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
        FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
        AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
        LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
        OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
        SOFTWARE.
        
Project-URL: Source, https://github.com/Computational-Mechanics-Materials-Lab/DI2008_Python
Requires-Python: >=3.10
Description-Content-Type: text/markdown
License-File: LICENSE
Requires-Dist: pyserial>=3.5
Requires-Dist: tomli; python_version < "3.11"
Dynamic: license-file

# DI2008-Python

## About
Interface for the DI-2008 in Python.

Python 3.10+

Modified from original interface in Python by DATAQ Instruments under MIT License

Maintainer: Clark Hensley ch3136@msstate.edu

## Getting Started
Install via pip from PyPI:
```sh
pip install di2008-python
```

See Available DI-2008s:
```py
from di2008_python import print_all_di2008_metadata
print_all_di2008_metadata()
```

Instantiate DI2008 Object with Dictionary of Parameters:
```py
from di2008_python import (
    DI2008,
    DI2008AnalogChannels,
    DI2008AllAnalogChannels,
    DI2008AnalogLayout,
    DI2008TCType,
    DI2008ScanRateSettings,
    DI2008FilterModes,
    DI2008SerialNums
)

# Create an array of DI-2008s with relevant settings
di2008_array = DI2008({
        # Global Settings
        DI2008AllAnalogChannels: (DI2008AnalogLayout.TC, DI2008TCType.K),
        DI2008ScanRateSettings.SRATE: 4,
        DI2008ScanRateSettings.DEC: 1,
        DI2008ScanRateSettings.FILTER: {
            DI2008AllAnalogChannels: DI2008FilterModes.AVERAGE,
            },
        # Serial Numbers of DI-2008s to apply
        DI2008lSerialNums: [<DI-2008 Serial Num>, <DI-2008 Serial Num>, ...],
        # Overwriting settings for a given DI-2008 (Not one of the ones listed above)
        <DI-2008 Serial Num>: {
            DI2008AnalogChannels.CH1: (DI2008AnalogLayout.TC, DI2008TCType.N),
            DI2008ScanRateSettings.FILTER: {
                DI2008AnalogChannels.CH1: DI2008FilterModes.LAST_POINT,
                }
            }

# Synchronized start of DI2008s
di2008_array.start_di2008s()

# Read from the DI2008s
while True:
    data = di2008_array.read_di2008s()
    print(data)
```

This interface uses named enumerations to ensure that what settings are being used is clear and concise

Currently, this package supports configuring and using up to 16 DI-2008s via ChannelStretch synchronization, and using any configuration of the Analog Channels. As of version 1.2.2, the digital channels, as well as the Event, Record, Rate, and Count channels are not yet supported.

*Note About Bandwidth:*
Per the DI-2008 Protocol, if a single analog channel is enabled, the maximum sample rate of the DI-2008 is 2000 Hz, and if two or more analog channels are enabled, the maximum sample rate of the DI-2008 is 200 Hz. However, in this current implementation, that rate must be again divided by the number of enabled channels. Thus, 2 channels have a maximum sample rate of 100 Hz, and all 8 enabled channels can be sampled at, at most, 25 Hz. This is a known issue and work to address it is ongoing.

## Current Features:
* Thermocouples
* ADC Reading
* Changing Scan Rate, Decimation, and Filtering Mode
* Automatic ChannelStretch Synchronized Initialization
* Enforce cleanup on stopping
* Changing Packet Size
* Interface with the `info` operator

## Planned Features:
* Reading configuration from .json/.toml files as well as raw Python dictionaries
    * The backend for this is implement as of version 1.4.0. The API interface needs work.
* Digital Channels
* Specify Digital Input as well as Output
* CJCDelta
* Rate Measurement
* LED Color