Metadata-Version: 2.1
Name: module_qc_tools
Version: 2.1.1
Summary: Module qc tools
Project-URL: Homepage, https://gitlab.cern.ch/atlas-itk/pixel/module/module-qc-tools
Project-URL: Bug Tracker, https://gitlab.cern.ch/atlas-itk/pixel/module/module-qc-tools/-/issues
Project-URL: Source, https://gitlab.cern.ch/atlas-itk/pixel/module/module-qc-tools
Author-email: Jay Chan <jay.chan@cern.ch>
Maintainer-email: Giordon Stark <gstark@cern.ch>
License: Copyright (c) 2018 The Python Packaging Authority
        
        Permission is hereby granted, free of charge, to any person obtaining a copy
        of this software and associated documentation files (the "Software"), to deal
        in the Software without restriction, including without limitation the rights
        to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
        copies of the Software, and to permit persons to whom the Software is
        furnished to do so, subject to the following conditions:
        
        The above copyright notice and this permission notice shall be included in all
        copies or substantial portions of the Software.
        
        THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
        IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
        FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
        AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
        LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
        OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
        SOFTWARE.
License-File: LICENSE
Classifier: License :: OSI Approved :: MIT License
Classifier: Operating System :: OS Independent
Classifier: Programming Language :: Python :: 3
Requires-Python: >=3.7
Requires-Dist: importlib-resources; python_version < '3.9'
Requires-Dist: jsonschema
Requires-Dist: module-qc-data-tools>=1.0.11
Requires-Dist: numpy
Requires-Dist: pandas
Requires-Dist: pre-commit
Requires-Dist: requests
Requires-Dist: tabulate
Requires-Dist: typer>=0.9.0
Requires-Dist: urllib3<2,>=1.26.11; 'el7.x86_64' in platform_release
Description-Content-Type: text/markdown

# module-qc-tools v2.1.1

A general python tool for running ITkPixV1.1 module QC tests

## Table of contents

1. [Requirements](#requirements)
2. [Installation](#installation)
3. [Usage](#usage)
4. [Configuration and external commands](#configuration-and-external-commands)
5. [Measurements](#measurements)
   1. [Sensor IV measurement](#iv-measure)
   2. [Data Transmission](#data-transmission)
   3. [ADC calibration](#adc-calibration)
   4. [Analog readback](#analog-readback)
   5. [SLDOVI](#sldovi)
   6. [VCal calibration](#vcal-calibration)
   7. [Injection capacitance](#injection-capacitance)
   8. [Low Power Mode](#low-power-mode)
   9. [Overvoltage protection](#overvoltage-protection)
   10. [Undershunt protection](#undershunt-protection)
6. [Output data](#output-data)
7. [Schema check](#schema-check)
8. [Time Estimates](#time-estimates)
9. [Upload results to localDB](#upload-results-to-localdb)
10. [For developer](#for-developer)

## Requirements

This tool requires users to have >= python3.7 with the following packages
installed:

- `numpy`
- `tabulate`

Check the local python version with `python -V`. If the local python version is
lower than Python 3.7, set up a virtual python environment following the
instructions [here](https://itk.docs.cern.ch/general/Virtual_Environments/).

In addition, users shall install `YARR` and prepare external scripts for remote
control of power supply, multimeter and NTC readout. The external scripts shall
follow a fixed format, which is detailed in the later section.

## Installation

This package may be accessed by cloning from gitlab or by installing it via pip.

### via clone

Use this method if you want to use the latest version of the package from
gitlab. First clone the project:

```
git clone https://gitlab.cern.ch/atlas-itk/pixel/module/module-qc-tools.git
```

Upon a successful checkout, `cd` to the new `module-qc-tools` directory and run
the following to install the necessary software:

```verbatim
$ python -m venv venv
$ source venv/bin/activate
$ python -m pip install --upgrade pip
$ python -m pip install -e .
```

### via pip

Use this method if you want to use the latest stable (versioned) release of the
package.

```
python -m venv venv
source venv/bin/activate
python -m pip install -U pip
python -m pip install -U pip module-qc-tools==2.1.1
```

## Usage

After installation, one just needs to enter the virtual environment in each new
session to use the scripts:

```verbatim
source venv/bin/activate
```

The first step in using this package is to set up the
[Configuration and external commands](#configuration-and-external-commands)
input json file. This json file is then passed as input to the scripts used to
run the [Measurements](#measurements).

## Configuration and external commands

All the configuration/settings are defined in a single json file. The layer
information needed for the different power settings is extracted from the
module's serial number. Examples are provided in `$(module-qc-tools
--prefix)/configs/':

```
example_merged_vmux.json
example_separate_vmux.json
```

<details> <summary> $(module-qc-tools --prefix)/configs/example_merged_vmux.json </summary>

```json
{
        "yarr": {
                "run_dir": "../Yarr",
                "controller": "configs/controller/specCfg-rd53b-16x1.json",
                "scanConsole_exe": "./bin/scanConsole",
                "write_register_exe": "./bin/write-register",
                "read_adc_exe": "./bin/read-adc",
                "switchLPM_exe": "./bin/switchLPM",
                "lpm_digitalscan": "configs/scans/rd53b/lpm_digitalscan.json",
                "read_ringosc_exe": "./bin/rd53bReadRingosc"
        },
        "power_supply": {
                "run_dir": "../labRemote",
                "on_cmd": "./build/bin/powersupply -e ./src/configs/input-hw.json -n PS -c 1 power-on",
                "off_cmd": "./build/bin/powersupply -e ./src/configs/input-hw.json -n PS -c 1 power-off",
                "set_cmd": "./build/bin/powersupply -e ./src/configs/input-hw.json -n PS -c 1 set-current {i} {v}",
                "getI_cmd": "./build/bin/powersupply -e ./src/configs/input-hw.json -n PS -c 1 get-current",
                "getV_cmd": "./build/bin/powersupply -e ./src/configs/input-hw.json -n PS -c 1 get-voltage",
                "measI_cmd": "./build/bin/powersupply -e ./src/configs/input-hw.json -n PS -c 1 meas-current",
                "measV_cmd": "./build/bin/powersupply -e ./src/configs/input-hw.json -n PS -c 1 meas-voltage",
                "n_try": 0,
                "success_code": 0
        },
        "multimeter": {
                "run_dir": "../labRemote",
                "dcv_cmd": [
                        "./build/bin/meter -e ./src/configs/input-hw-min_marija.json -n myVmuxMeter -c 0 meas-voltage"
                ],
                "n_try": 0,
                "success_code": 0
        },
        "ntc": {
                "run_dir": "../labremote_devel/scripts",
                "cmd": "python measureT.py",
                "n_try": 0,
                "success_code": 0
        },
        "tasks": {
                "GENERAL": {...},
                "ADC_CALIBRATION": {...},
                "ANALOG_READBACK": {...},
                "SLDO": {...},
		            "VCAL_CALIBRATION": {...},
		            "INJECTION_CAPACITANCE": {...}
        }
}
```

</details>

The major blocks (e.g. `yarr`, `power_supply`, `multimeter`, `ntc`) correspond
to how the scripts will communicate with the module via YARR and how they will
communicate with the lab equipment. Each of these blocks are explained in the
following sections. The `task` block specifies the settings of each scan
performed by the scripts, and will be explained in the
[Measurements](#measurements) section.

### yarr

The `yarr` block specifies the path to the `YARR` repository as well as the
corresponding YARR configuration files.

- `run_dir`: path (relative or absolute) to the directory where `YARR` commands
  should be run
- `controller`: path (relative to `run_dir` or absolute) to the controller file
- `scanConsole_exe`: path (relative to `run_dir` or absolute) to the
  `scanConsole` executable
- `write_register_exe`: path (relative to `run_dir` or absolute) to the
  `write_register` executable
- `read_register_exe`: path (relative to `run_dir` or absolute) to the
  `read_register` executable
- `read_adc_exe`: path (relative to `run_dir` or absolute) to the `read_adc`
  executable
- `switchLPM_exe`: path (relative to `run_dir` or absolute) to the `switchLPM`
  executable
- `lpm_digitalscan`: path (relative to `run_dir` or absolute) to the low-power
  mode digital scan in YARR
- `read_ringosc_exe`: path (relative to `run_dir` or absolute) to the
  `read_ringosc_exe` executable
- `success_code`: exit status that indicates success. The default is 0 besides
  `configure`, which has exit status 1 for success. The user do not need to set
  the `success_code` as the default in QC software is synchronized with YARR.

### power_supply

The `power_supply` block specifies the path and the commands for handling the
low voltage power supply

- `run_dir`: path (relative or absolute) to the directory where `power_supply`
  commands should be run
- `on_cmd`: command to turn on the power supply with specified voltage and
  current. Use the syntax `{v}` and `{i}` to represent the voltage and current
  that are to be given as input arguments
- `off_cmd`: command to turn off the power supply
- `set_cmd`: command to set voltage and current for power supply. Use the syntax
  `{v}` and `{i}` to represent the voltage and current that are to be given as
  input arguments
- `getI_cmd`: command to inquire the set current of the power supply. This
  command shall return a std output which represents the value of the current
  (float in the unit of [A]). For example, when I = 5.2A, `getI_cmd` returns std
  output = `5.2`.
- `getV_cmd`: command to measure the output voltage of the power supply. This
  command shall return a std output which represents the value of the voltage
  (float in the unit of [V]). For example, when V = 1.8V, `getV_cmd` returns std
  output = `1.8`.
- `measI_cmd`: command to measure the output current of the power supply. This
  command shall return a std output which represents the value of the current
  (float in the unit of [A]). For example, when I = 5.2A, `measI_cmd` returns
  std output = `5.2`.
- `measV_cmd`: command to inquire the set voltage of the power supply. This
  command shall return a std output which represents the value of the voltage
  (float in the unit of [V]). For example, when V = 1.8V, `measV_cmd` returns
  std output = `1.8`.
- `n_try`: number of re-tries in case the script fails to read from the power
  supply
- `success_code`: exit status that indicates success. The default is 0.

### high_voltage

Similar to the `power_supply` block, the `high_voltage` block specifies the path
and the commands for handling the high voltage power supply needed for leakage
current vs. bias voltage (IV) measurements.

- `ramp_cmd`: (optional) command to ramp the high voltage to the target value
  without measuring. If no command is available or provided, module-qc-tools
  will use its internal ramp function.
- `getI_cmd`: command to measure the leakage current of the high voltage. This
  command shall return a std output which represents the value of the current
  (float in the unit of [A]). For example, when I = 1uA, `getI_cmd` returns std
  output = `0.000001`.
- `polarity`: indicator if normal polarity (default 1) or reverse polarity (-1)
  is used. For power supplies that accept and output both positive and negative
  values of the bias voltage, the polarity is `1`. For power supplies that only
  accept and output a single polarity, this setting is `-1` and the wiring
  should be adapted accordingly.

### multimeter

The `multimeter` block specifies the path and the commands for handling the
multimeter

- `run_dir`: path (relative or absolute) to the directory where `multimeter`
  commands should be run
- `dcv_cmd`: list of commands to measure voltage from the multimeter. Each
  command corresponds to a single multimeter channel (only the used channels
  need to be listed). Each command returns a std output which represents the
  value of measured voltage (float in the unit of [V]). For example, when V =
  0.352V, `dcv_cmd` returns std output = `0.352`.
- `n_try`: number of re-tries in case the script fails to read from the
  multimeter
- `success_code`: exit status that indicates success. The default is 0.

### ntc

The `ntc` block specifies the path and the commands for handling the NTC

- `run_dir`: path (relative or absolute) to the directory where `ntc` commands
  should be run
- `cmd`: command to measure temperature from the module NTC. The command returns
  a std output which represents the value of measured temperature (float in the
  unit of [C]). For example: when T = 36.2C, `cmd` returns std output = `36.2`.
- `n_try`: number of re-tries in case the script fails to read from the ntc
- `success_code`: exit status that indicates success. The default is 0.

### tasks

The `tasks` block starts with the `GENERAL` section that specifies the
layer-dependent power settings:

- `v_max`: the voltage to be set to the power supply (i.e. the max voltage since
  the power supply should operate in constant current)
- `i_config`: the current at which the module should be configured
- `share_vmux`: whether to merge the Vmux channels or not
- `v_mux_channels`: multimeter channel to measure the Vmux for each chip
  (correspond to each element in the dcv_cmd in the multimeter block)

The main part of the `tasks` block is to specify all
[measurements](#measurements) as listed below.

## Measurements

An overview of the steps in the module QC procedure is documented in the
[Electrical specification and QC procedures for ITkPixV1.1 modules](https://gitlab.cern.ch/atlas-itk/pixel/module/itkpix-electrical-qc/)
document and in
[this spreadsheet](https://docs.google.com/spreadsheets/d/1qGzrCl4iD9362RwKlstZASbhphV_qTXPeBC-VSttfgE/edit#gid=989740987).
Each measurement is performed with one script. All scripts assume that the
modules to be tested are already powered on.

### IV MEASURE

`measurement-IV-MEASURE`

This script will test the sensor leakage current vs. reverse bias voltage
(`task = IV_MEASURE`) as specified in the input configuration json file (i.e.
`$(module-qc-tools --prefix)/configs/example_merged_vmux.json`).

<details> <summary> Configuration settings </summary>

- `v_min`: the starting voltage of this measurement
- `v_max`: the end voltage of this measurement
- `i_max`: the current compliance throughout the measurement
- `n_points`: how many points should be measured depending on the required
  voltage steps (i.e. 1V for 3D and 5V for planar modules)
- `settling_time`: delay in seconds between setting a bias voltage and reading
  the current

</details>

<details> <summary> Help message </summary>

```
$ measurement-IV-MEASURE --help
usage: measurement-IV-MEASURE [-h] [-c CONFIG] [-o OUTPUT_DIR] [-m MODULE_CONNECTIVITY] [--verbosity LEVEL] [--site STRING] [-t FLOAT] [--vdepl FLOAT]

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file
  -o OUTPUT_DIR, --output-dir OUTPUT_DIR
                        output directory
  -m MODULE_CONNECTIVITY, --module-connectivity MODULE_CONNECTIVITY
                        path to the module connectivity. Used also to identify the module SN, and to set the default output directory.
  -v VERBOSITY, --verbosity VERBOSITY
                        Log level [options: DEBUG, INFO (default) WARNING, ERROR]
  --site STR            Your testing site. Required when submitting results to the database. Please use institute codes defined on production DB, i.e. "LBNL_PIXEL_MODULES" for LBNL, "IRFU" for Paris-Saclay, ...
  --vdepl FLOAT         Depletion voltage from production database [default: None]
```

</details>

<details> <summary> Example </summary>

```
measurement-IV-MEASURE -c $(module-qc-tools --prefix)/configs/example_merged_vmux.json -m ~/module_data/20UPGR91301046/20UPGR91301046_L2_LP.json
```

</details>

<details> <summary> Example command to run on the toy emulator </summary>

```
measurement-IV-MEASURE -c $(module-qc-tools --prefix)/configs/emulator_merged_vmux.json -o emulator/outputs
```

</details>

### Data Transmission

`measurement-DATA-TRANSMISSION`

This script will run the data transmission (`task = DATA_TRANSMISSION`) as
specified in the input configuration json file (i.e.
`$(module-qc-tools --prefix)/configs/example_merged_vmux.json`).

<details> <summary> Configuration settings </summary>

- `MonitorV`: list of VMUX channels to be set

</details>

<details> <summary> Help message </summary>

```
$ measurement-DATA-TRANSMISSION --help
usage: measurement-DATA-TRANSMISSION [-h] [-c CONFIG] [-o OUTPUT_DIR] [--verbosity LEVEL] [-m MODULE_CONNECTIVITY] [--perchip]

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file
  -o OUTPUT_DIR, --output-dir OUTPUT_DIR
                        output directory
  -m MODULE_CONNECTIVITY, --module-connectivity MODULE_CONNECTIVITY
                        path to the module connectivity. Used also to identify the module SN, and to set the default output directory
  -v VERBOSITY, --verbosity VERBOSITY
                        Log level [options: DEBUG, INFO (default) WARNING, ERROR]
  --perchip           Store results in one file per chip (default: one file per module)
  --site,           Your testing site. Required when submitting results to the database. Please use institute codes defined on production DB, i.e. "LBNL_PIXEL_MODULES" for LBNL, "IRFU" for Paris-Saclay, ...
  --dry-run,        Specify if the controller config should not be updated. Default is "False".
```

</details>

<details> <summary> Example </summary>

```
measurement-DATA-TRANSMISSION -c $(module-qc-tools --prefix)/configs/example_merged_vmux.json -m ~/module_data/20UPGR91301046/20UPGR91301046_L2_warm.json
```

</details>

<details> <summary> Example command to run on the toy emulator </summary>

```
measurement-DATA-TRANSMISSION -c $(module-qc-tools --prefix)/configs/emulator_merged_vmux.json -o emulator/outputs/
```

</details>

### ADC calibration

`measurement-ADC-CALIBRATION`

This script will run the ADC calibration (`task = ADC_CALIBRATION`) as specified
in the input configuration json file (i.e.
`$(module-qc-tools --prefix)/configs/example_merged_vmux.json`).

<details> <summary> Configuration settings </summary>

- `MonitorV`: list of Vmux channels to be measured
- `InjVcalRange`: the range of the calibration injection circuit(1: a large
  range and 0: a small range i.e. half the large range but a finer step)
- `Range`: the DACs scan range ["start", "stop", "step"]

</details>

<details> <summary> Help message </summary>

```
$ measurement-ADC-CALIBRATION --help
usage: measurement-ADC-CALIBRATION [-h] [-c CONFIG] [-o OUTPUT_DIR] [--verbosity LEVEL] [-m MODULE_CONNECTIVITY] [--perchip]

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file
  -o OUTPUT_DIR, --output-dir OUTPUT_DIR
                        output directory
  -m MODULE_CONNECTIVITY, --module-connectivity MODULE_CONNECTIVITY
                        path to the module connectivity. Used also to identify the module SN, and to set the default output directory
  -v VERBOSITY, --verbosity VERBOSITY
                        Log level [options: DEBUG, INFO (default) WARNING, ERROR]
  --perchip           Store results in one file per chip (default: one file per module)
  --site,           Your testing site. Required when submitting results to the database. Please use institute codes defined on production DB, i.e. "LBNL_PIXEL_MODULES" for LBNL, "IRFU" for Paris-Saclay, ...
```

</details>

<details> <summary> Example </summary>

```
measurement-ADC-CALIBRATION -c $(module-qc-tools --prefix)/configs/example_merged_vmux.json -m ~/module_data/20UPGR91301046/20UPGR91301046_L2_warm.json
```

</details>

<details> <summary> Example command to run on the toy emulator </summary>

```
measurement-ADC-CALIBRATION -c $(module-qc-tools --prefix)/configs/emulator_merged_vmux.json -o emulator/outputs/
```

</details>

### Analog readback

`measurement-ANALOG-READBACK`

This script will measure all internal voltages available through VMUX and IMUX,
measure the chip temperature, and measure VDDA/VDDD/ROSC vs Trim. channels. The
scan settings are defined in the `task = ANALOG_READBACK` block of the input
configuration file (i.e.
`$(module-qc-tools --prefix)/configs/example_merged_vmux.json`). The NTC needs
to be set in order to run this script, so that the temperature can be read.

<details> <summary> Configuration settings </summary>

- `v_mux`: list of Vmux channels to be measured
- `i_mux`: list of Imux channels to be measured
- `v_mux_ntc`: list of Vmux channels to be measured for ntc temperature
- `i_mux_ntc`: list of Imux channels to be measured for ntc temperature
- `v_mux_tempsens`: list of Vmux channels to be measured for 3 temperature
  sensors
- `MonSensSldoDigSelBias`: Bias 0 and 1 for MOS sensor near digital SLDO
- `MonSensSldoAnaSelBias`: Bias 0 and 1 for MOS sensor near analog SLDO
- `MonSensAcbSelBias`: Bias 0 and 1 for MOS sensor near center
- `MonSensSldoDigDem`: Dem 0-15 for MOS sensor near digital SLDO
- `MonSensSldoAnaDem`: Dem 0-15 for MOS sensor near analog SLDO
- `MonSensAcbDem`: Dem 0-15 for MOS sensor near center
- `SldoTrimA`: Sldo analog Trim 0-15
- `SldoTrimD`: Sldo digital Trim 0-15

</details>

<details> <summary> Help message </summary>

```
usage: measurement-ANALOG-READBACK [-h] [-c CONFIG] [-o OUTPUT_DIR]
                                   [-m MODULE_CONNECTIVITY] [--verbosity LEVEL] [--perchip]

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file
  -o OUTPUT_DIR, --output-dir OUTPUT_DIR
                        output directory
  -m MODULE_CONNECTIVITY, --module-connectivity MODULE_CONNECTIVITY
                        path to the module connectivity. Used also
                        to identify the module SN, and to set the default output directory
  -v VERBOSITY, --verbosity VERBOSITY
                        Log level [options: DEBUG, INFO (default) WARNING, ERROR]
  --perchip           Store results in one file per chip (default: one file per module)
  --site,           Your testing site. Required when submitting results to the database. Please use institute codes defined on production DB, i.e. "LBNL_PIXEL_MODULES" for LBNL, "IRFU" for Paris-Saclay, ...
```

</details>

<details> <summary> Example </summary>

```
measurement-ANALOG-READBACK -c $(module-qc-tools
--prefix)/configs/example_merged_vmux.json -m
~/module_data/20UPGR91301046/20UPGR91301046_L2_warm.json

```

</details>

<details> <summary> Example command to run on the toy emulator </summary>

```
measurement-ANALOG-READBACK -c $(module-qc-tools
--prefix)/configs/emulator_merged_vmux.json -o emulator/outputs

```

</details>

### SLDOVI

`measurement-SLDO`

This script will run the VI scans (`task = SLDO`) as specified in the input
configuration json file (i.e.
`$(module-qc-tools --prefix)/configs/example_merged_vmux.json`).

<details> <summary> Configuration settings </summary>

- `i_min`: the minimum current of the VI scan
- `i_max`: the maximum current of the VI scan
- `n_points`: how many points should be measured (equally spread between the max
  of the min currents)
- `extra_i`: extra current points to be measured
- `v_mux`: list of Vmux channels to be measured
- `i_mux`: list of Imux channels to be measured

</details>

<details> <summary> Help message </summary>

```
$ measurement-SLDO --help
usage: measurement-SLDO [-h] [-c CONFIG] [-o OUTPUT_DIR] [-m MODULE_CONNECTIVITY] [--perchip]
                        [--verbosity LEVEL]

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file
  -o OUTPUT_DIR, --output-dir OUTPUT_DIR
                        output directory
  -m MODULE_CONNECTIVITY, --module-connectivity MODULE_CONNECTIVITY
                        path to the module connectivity. Used also to identify the module SN, and to
                        set the default output directory
  --perchip           Store results in one file per chip (default: one file per module)
  -v VERBOSITY, --verbosity VERBOSITY
                        Log level [options: DEBUG, INFO (default) WARNING, ERROR]
  --site,           Your testing site. Required when submitting results to the database. Please use institute codes defined on production DB, i.e. "LBNL_PIXEL_MODULES" for LBNL, "IRFU" for Paris-Saclay, ...
```

</details>

<details> <summary> Example </summary>

```
measurement-SLDO -c $(module-qc-tools --prefix)/configs/example_merged_vmux.json -m ~/module_data/20UPGR91301046/20UPGR91301046_L2_warm.json
```

</details>

<details> <summary> Example command to run on the toy emulator </summary>

```
measurement-SLDO -c $(module-qc-tools --prefix)/configs/emulator_merged_vmux.json -o emulator/outputs
```

</details>

### VCal calibration

`measurement-VCAL-CALIBRATION`

This script will run the VCal calibration (`task = VCAL_CALIBRATION`) as
specified in the input configuration json file (i.e.
`$(module-qc-tools --prefix)/configs/example_merged_vmux.json`).

<details> <summary> Configuration settings </summary>

- `InjVcalRange`: the range of the calibration injection circuit(1: a large
  range and 0: a small range i.e. half the large range but a finer step)
- `MonitorV`: two DACs VMUX assignments Vcal_med(8) and Vcal_high(7)
- `MonitorV_GND`: the GNDA VMUX assignment 30
- `Large_Range`: the large DACs scan range ["start", "stop", "step"]
- `Small_Range`: the small DACs scan range ["start", "stop", "step"]

</details>

<details> <summary> Help message </summary>

```
$ measurement-VCAL-CALIBRATION --help
usage: measurement-VCAL-CALIBRATION [-h] [-c CONFIG] [-o OUTPUT_DIR] [-m MODULE_CONNECTIVITY] [--verbosity LEVEL] [--perchip]

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file
  -o OUTPUT_DIR, --output-dir OUTPUT_DIR
                        output directory
  -m MODULE_CONNECTIVITY, --module-connectivity MODULE_CONNECTIVITY
                        path to the module connectivity. Used also to identify the module SN, and to
                        set the default output directory
  -v VERBOSITY, --verbosity VERBOSITY
                        Log level [options: DEBUG, INFO (default) WARNING, ERROR]
  --perchip           Store results in one file per chip (default: one file per module)
  --site,           Your testing site. Required when submitting results to the database. Please use institute codes defined on production DB, i.e. "LBNL_PIXEL_MODULES" for LBNL, "IRFU" for Paris-Saclay, ...
```

</details>

<details> <summary> Example </summary>

```
measurement-VCAL-CALIBRATION -c $(module-qc-tools
--prefix)/configs/example_merged_vmux.json -m
~/module_data/20UPGR91301046/20UPGR91301046_L2_warm.json

```

</details>

<details> <summary> Example command to run on the toy emulator </summary>

```
measurement-VCAL-CALIBRATION -c $(module-qc-tools
--prefix)/configs/emulator_merged_vmux.json -o emulator/outputs/

```

</details>

### Injection capacitance

`measurement-INJECTION-CAPACITANCE`

This script will run the injection capacitance measurement
(`task = INJECTION_CAPACITANCE`) as specified in the input configuration json
file (i.e. `$(module-qc-tools --prefix)/configs/example_merged_vmux.json`).

<details> <summary> Configuration settings </summary>

- `n_meas`: number of measurements to perform
- `v_mux`: list of Vmux channels to be measured
- `i_mux`: list of Imux channels to be measured

</details>

<details> <summary> Help message </summary>

```
usage: measurement-INJECTION-CAPACITANCE [-h] [-c CONFIG]
                                         [-o OUTPUT_DIR] [-m MODULE_CONNECTIVITY] [--verbosity]
                                         [--perchip]

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file
  -o OUTPUT_DIR, --output-dir OUTPUT_DIR
                        output directory
  -m MODULE_CONNECTIVITY, --module-connectivity MODULE_CONNECTIVITY
                        path to the module connectivity. Used also
                        to identify the module SN, and to set the default output directory
  -v VERBOSITY, --verbosity VERBOSITY
                        Log level [options: DEBUG, INFO (default) WARNING, ERROR]
  --perchip           Store results in one file per chip (default: one file per module)
  --site,           Your testing site. Required when submitting results to the database. Please use institute codes defined on production DB, i.e. "LBNL_PIXEL_MODULES" for LBNL, "IRFU" for Paris-Saclay, ...
```

</details>

<details> <summary> Example </summary>

```
measurement-INJECTION-CAPACITANCE -c $(module-qc-tools
--prefix)/configs/example_merged_vmux.json -m
~/module_data/20UPGR91301046/20UPGR91301046_L2_warm.json

```

</details>

<details> <summary> Example command to run on the toy emulator </summary>

```
measurement-INJECTION-CAPACITANCE -c $(module-qc-tools
--prefix)/configs/emulator_merged_vmux.json -o emulator/outputs/

```

</details>

### Low Power Mode

`measurement-LP-MODE`

This script will run the low power mode test (`task = LP_MODE`) as specified in
the input configuration json file (i.e.
`$(module-qc-tools --prefix)/configs/example_merged_vmux.json`).

<details> <summary> Configuration settings </summary>

- `v_max`: the voltage to be set to the power supply specific to this
  measurement
- `i_config`: the current at which the module should be configured specific for
  this measurement
- `v_mux`: list of Vmux channels to be measured
- `i_mux`: list of Imux channels to be measured

</details>

<details> <summary> Help message </summary>

```
usage: measurement-LP-MODE [-h] [-c CONFIG] [-o OUTPUT_DIR]
                                   [-m MODULE_CONNECTIVITY] [--verbosity LEVEL] [--perchip]

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file
  -o OUTPUT_DIR, --output-dir OUTPUT_DIR
                        output directory
  -m MODULE_CONNECTIVITY, --module-connectivity MODULE_CONNECTIVITY
                        path to the module connectivity. Used also
                        to identify the module SN, and to set the default output directory.
                        Note that this measurement should be used using LP config therefore
                        this should point to LP connectivity.
  -v VERBOSITY, --verbosity VERBOSITY
                        Log level [options: DEBUG, INFO (default) WARNING, ERROR]
  --perchip           Store results in one file per chip (default: one file per module)
  --site,           Your testing site. Required when submitting results to the database. Please use institute codes defined on production DB, i.e. "LBNL_PIXEL_MODULES" for LBNL, "IRFU" for Paris-Saclay, ...
```

</details>

<details> <summary> Example </summary>

```
measurement-LP-MODE -c $(module-qc-tools --prefix)/configs/example_merged_vmux.json -m ~/module_data/20UPGR91301046/20UPGR91301046_L2_LP.json
```

</details>

<details> <summary> Example command to run on the toy emulator </summary>

```
measurement-LP-MODE -c $(module-qc-tools --prefix)/configs/emulator_merged_vmux.json -o emulator/outputs/
```

</details>

### Overvoltage Protection

`measurement-OVERVOLTAGE-PROTECTION`

This script will test the Overvolatge Protection (OVP)
(`task = OVERVOLTAGE_PROTECTION`) as specified in the input configuration json
file (i.e. `$(module-qc-tools --prefix)/configs/example_merged_vmux.json`).

<details> <summary> Configuration settings </summary>

- `v_max`: the voltage to be set to the power supply specific to this
  measurement
- `i_config`: the current at which the module should be configured specific for
  this measurement
- `v_mux`: list of Vmux channels to be measured
- `i_mux`: list of Imux channels to be measured

</details>

<details> <summary> Help message </summary>

```
$ measurement-OVERVOLTAGE-PROTECTION --help
usage: measurement-OVERVOLTAGE-PROTECTION [-h] [-c CONFIG] [-o OUTPUT_DIR] [-m MODULE_CONNECTIVITY] [--perchip] [--verbosity LEVEL]

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file
  -o OUTPUT_DIR, --output-dir OUTPUT_DIR
                        output directory
  -m MODULE_CONNECTIVITY, --module-connectivity MODULE_CONNECTIVITY
                        path to the module connectivity. Used also to identify the module SN, and to set the default output directory.
                        Note that this measurement should be used using LP config therefore
                        this should point to LP connectivity.
  --perchip             Store results in one file per chip (default: one file per module)
  -v VERBOSITY, --verbosity VERBOSITY
                        Log level [options: DEBUG, INFO (default) WARNING, ERROR]
  --site,           Your testing site. Required when submitting results to the database. Please use institute codes defined on production DB, i.e. "LBNL_PIXEL_MODULES" for LBNL, "IRFU" for Paris-Saclay, ...

```

</details>

<details> <summary> Example </summary>

```
measurement-OVERVOLTAGE-PROTECTION -c $(module-qc-tools --prefix)/configs/example_merged_vmux.json -m ~/module_data/20UPGR91301046/20UPGR91301046_L2_LP.json
```

</details>

<details> <summary> Example command to run on the toy emulator </summary>

```
measurement-OVERVOLTAGE-PROTECTION -c $(module-qc-tools --prefix)/configs/emulator_merged_vmux.json -o emulator/outputs
```

</details>

### Undershunt Protection

`measurement-UNDERSHUNT-PROTECTION`

This script will test the Undershunt Protection (USP)
(`task = UNDERSHUNT_PROTECTION`) as specified in the input configuration json
file (i.e. `$(module-qc-tools --prefix)/configs/example_merged_vmux.json`).

<details> <summary> Configuration settings </summary>

- `v_max`: the voltage to be set to the power supply specific to this
  measurement
- `i_config`: the current at which the module should be configured specific for
  this measurement
- `v_mux`: list of Vmux channels to be measured
- `i_mux`: list of Imux channels to be measured

</details>

<details> <summary> Help message </summary>

```
$ measurement-UNDERSHUNT-PROTECTION --help
usage: measurement-UNDERSHUNT-PROTECTION [-h] [-c CONFIG] [-o OUTPUT_DIR] [-m MODULE_CONNECTIVITY] [--perchip]
[--verbosity LEVEL]

optional arguments:
  -h, --help            show this help message and exit
  -c CONFIG, --config CONFIG
                        Config file
  -o OUTPUT_DIR, --output-dir OUTPUT_DIR
                        output directory
  -m MODULE_CONNECTIVITY, --module-connectivity MODULE_CONNECTIVITY
                        path to the module connectivity. Used also to identify the module SN, and to set the default
output directory.
                        Note that this measurement should be used using LP config therefore
                        this should point to LP connectivity.
  --perchip             Store results in one file per chip (default: one file per module)
  -v VERBOSITY, --verbosity VERBOSITY
                        Log level [options: DEBUG, INFO (default) WARNING, ERROR]

```

</details>

<details> <summary> Example </summary>

```
measurement-UNDERSHUNT-PROTECTION -c $(module-qc-tools --prefix)/configs/example_merged_vmux.json -m
~/module_data/20UPGR91301046/20UPGR91301046_L2_LP.json
```

</details>

<details> <summary> Example command to run on the toy emulator </summary>

```
measurement-UNDERSHUNT-PROTECTION -c $(module-qc-tools --prefix)/configs/emulator_merged_vmux.json -o
emulator/outputs
```

</details>

## Output data

The output of the measurements follows the structure below:

```
|Measurements
   |<test_type>
   |VCAL_CALIB
       |<timestamp>
       |<YYYY-MM-DD_HHMMSS>
           |<chip_name/module_serial_number>.json
```

The test-type of each measuremnt is the corresponding test-code used in the
Production Data Base. The naming of each measuremnet script is chosen to be the
same as the test-type. The timestamp is chosen to be the start time of the
measurement.

## Schema check

The schema for the output json files is checked based on the schema files
specified in the folder `schema`. To run the common schema check for all test
outputs, do:

```
jsonschema --instance [path to output json files] $(module-qc-tools
--prefix)/schema/common.json

```

To run the further schema check for a specific test output, do:

```
jsonschema --instance [path to output json files] $(module-qc-tools
--prefix)/schema/[qc_task].json
```

<details> <summary> Example (with the emulator output files) </summary>

```
jsonschema --instance emulator/outputs/SLDO_reference/<timestamp>/chip1.json
$(module-qc-tools --prefix)/schema/common.json jsonschema --instance
emulator/outputs/SLDO_reference/<timestamp>/chip1.json $(module-qc-tools
--prefix)/schema/SLDO.json
```

</details>

## Time Estimates

| Measurement     | Duration |
| --------------- | -------- |
| ADC calib       | 00:02:12 |
| Analog Readback | 00:18:27 |
| SLDO VI         | 00:08:45 |
| Vcal calib      | 00:04:50 |
| Injection Cap.  | 00:00:50 |
| LP Mode         | 00:00:53 |
| OVP             | 00:00:27 |

## Upload results to localDB

The output measurement files can be uploaded to localDB using the following
command:

```
 module-qc-tools-upload --path PATH --host HOST --port PORT
```

Given a path to a directory with the output files, the script will recursively
search the directory and upload all files with the `.json` extension. Supply the
option `--dry-run` to see which files the script finds without uploading to
localDB.

<details> <summary> Help message </summary>

```
$ module-qc-tools-upload -h
usage: module-qc-tools-upload [-h] [--path PATH] [--host HOST] [--port PORT] [-n]

Walk through the specified directory (recursively) and attempt to submit all json files to LocalDB as the QC measurement

optional arguments:
  -h, --help     show this help message and exit
  --path PATH    Path to directory with output measurement files
  --host HOST    localDB server, default is localhost
  --port PORT    localDB port, default is 5000
  -n, --dry-run  Dry-run, do not submit to localDB.
```

</details>

## For Developer

### versioning

In case you need to tag the version of the code, you need to have either `hatch`
or `pipx` installed.

1. Activate python environment, e.g. `source venv/bin/activate`.
2. Run `python -m pip install hatch` or `python -m pip install pipx`.

You can bump the version via:

```
pipx run hatch run tag x.y.z

# or

hatch run tag x.y.z
```

where `x.y.z` is the new version to use. This should be run from the default
branch (`main` / `master`) as this will create a commit and tag, and push for
you. So make sure you have the ability to push directly to the default branch.

### pre-commit

Install pre-commit to avoid CI failure. Once pre-commit is installed, a git hook
script will be run to identify simple issues before submission to code review.

Instruction for installing pre-commit in a python environment:

1. Activate python environment, e.g. `source venv/bin/activate`.
2. Run `python3 -m pip install pre-commit`.
3. Run `pre-commit install` to install the hooks in `.pre-commit-config.yaml`.

After installing pre-commit, `.pre-commit-config.yaml` will be run every time
`git commit` is done. Redo `git add` and `git commit`, if the pre-commit script
changes any files.